FAMED CareSafe™

Automatic variable-pressure mattress filled with 17 independent air chambers powered by a pump. An additional foam pad protects the patient in case of damage to any of the chambers. The mattress is designed for use with patients with a very high risk of bedsores. The quiet mode of the pump, which injects 8 liters of air per minute into the chambers, allows for peaceful sleep and recovery. Variable or continuous low-pressure therapy mode and a system of automatic pressure adjustment according to the patient’s weight (up to 250 kg) ensure high therapeutic effectiveness. The waterproof and vapor-permeable coating keeps the patient’s skin from damage and keeps it in good condition.

SAFETY

The high-density foam and 17 individual air chambers ensure that the system functions properly even when individual units are damaged. Intelligent redistribution of pressure points on the largest areas of the body, reduction to zero pressure in the heel zone or minimization of tissue compression in the zones most prone to bedsores ensure safety and effective recovery. High-quality antibacterial and flexible cover reduces friction and prevents skin damage. Two CPR valves allow for immediate rescue procedures.

COMFORT

The multi-chamber system with two modes responds quickly to the pressure applied and adapts to the shape of the patient’s body. The polyester-polyamide cover minimizes shear forces and keeps the patient’s skin in proper condition. An additional layer of foam and division into two main anatomical zones provides comfort and speeds up recovery. Extremely quiet pump mode (less than 35 dB) ensures peaceful sleep and does dim the sounds of other medical equipment. A removable disinfectant-resistant cover, power cord management straps or maximum-fill mode make the work of medical personnel more convenient.

FUNCTIONALITY

The variable low-pressure therapy mode fills and empties two cells of the mattress alternately, except for the units located in the head section. Based on the patient’s weight, the pump calculates the air pressure needed to fill the cells, ensuring appropriate therapeutic conditions. A continuous low-pressure therapy mode continuously maintains the preset pressure. The maximum-fill mode quickly inflates the cells to a maximum firmness, making it easier to move and reposition the patient. The pump operates at four adjustable cycle times: 10, 15, 20 and 25 minutes. The mattress is designed to support patients weighing up to 250 kg.

interactive
plusminus
Convenient transport handles and loops for power cable management
plusminus
17 individual, removable air chambers
plusminus
Additional foam support for greater stability and safety
plusminus
High efficiency pump
plusminus
Two-part, waterproof zippered cover - two 180° zippers.
plusminus
Eight cable management ties with fastening clip protect cables from damage
plusminus
The safety straps at the bottom of the cover allow you to attach the mattress to the bed.
plusminus
Three pump modes: continuous low-pressure therapy mode, variable low-pressure therapy mode and maximum filling mode
plusminus
Four adjustable work cycles
plusminus
Two CPR valves allow immediate release of air from the chambers in emergency situations: a CPR valve in the pump and in the air connection to the mattress

PUMP

Highly efficient pump with quiet operation
Variable pressure mattress pump

Variable pressure mattress pump

  • The pump with a capacity of 8 liters per minute fills the mattress from zero to maximum mode in 22 minutes.
  • Variable mode of low-pressure therapy: the chambers are filled and emptied alternately in series of two, except for the chambers located in the patient’s head area.
  • Continuous (static) low pressure therapy mode: a fixed pressure is maintained in the chambers continuously.
  • Automatically calculates and adjusts the pressure and firmness of the mattress according to the patient’s weight.
  • The maximum filling mode allows the chambers to quickly fill to the maximum pressure ( firmness ) of the mattress, making it easier to move and reposition the patient.
  • The possibility of additional filling of the seat zone increases pressure in the air chambers located near the sacrum, making it easier for the patient to support and sit on the mattress.
  • Four adjustable cycle times: 10, 15, 20 and 25 minutes.
  • Automatic locking of the pump panel after 5 minutes of no activity to prevent unintended actions.
  • Two CPR valves allow immediate release of air from the chambers in emergency situations: a CPR valve in the pump and in the air connection to the mattress.
  • The transport connector cap can maintain air pressure in the chambers for up to 12 hours
  • Very silent operation.
  • The pressure range is 20 to 55 mmHg.
pompa

COMPATIBILITY

Match the anti-bedsore mattress to the hospital bed
Famed NANO
Famed NEXO

Famed NANO

Hospital bed compatible with hospital bed mattresses with a maximum thickness of 160 mm. Choosing a thicker mattress (up to 250 mm thick) requires the use of the PL-60 side rail adapter.

NANO

Famed NEXO

Hospital bed compatible with hospital bed mattresses with a maximum thickness of 160 mm. Choosing a thicker mattress (up to 250 mm thick) requires the use of the PL-60 side rail adapter.

NEXO
SPECIFICATION
Length 2000 mm
Width (overall) 850 mm
Maximum height 200 mm
Maximum load 250 kg

Check our products

To experience is to believe. We are happy to provide our products for testing so that the potential user can see their benefits before making the decision to purchase.

Contact us

Chętnie odpowiemy na każde zapytanie. Nasi specjaliści czekają.

+48 33 866 62 00

Send us your message

Czekamy na wiadomości. Odpowiemy w ciągu jednego dnia roboczego.

WYPEŁNIJ TERAZ

Visit us

Zapraszamy do umawiania wizyt z naszymi specjalistami w siedzibie naszej firmy.

MAPA DOJAZDU

Contact us